Industrial Nexus
English

EBRO

F012-A Double Flanged Isolation Butterfly Valve | EBRO

Product code: F012-A

Double flanged isolation butterfly valve for pipeline media isolation and sectional shutoff, available in DN 50 to DN 1400 sizes.

Category
Butterfly Valves
Operating Temperature Range
-40 °C to +200°C (depending on pressure, media, and materials)
Maximum Working Pressure
Max. 25 bar

The ebro F012-A is a double flanged isolation butterfly valve covering nominal sizes DN 50–DN 1400, with both a maximum working pressure and a maximum differential pressure of 25 bar. The valve supports multiple flange standards, installation in any orientation, and single flange installation, and complies with EN 593 and EN 12266 Leakage rate A. It is suitable for pipeline isolation in wastewater treatment, water supply and drainage, desalination, and power plant water systems.

Specifications

Nominal Diameter
DN 50 - DN 1400
Installation
Can be installed in any orientation; supports single flange installation
Connection Flanges
EN 1092 PN 6/10/16/25; ASME B16.5 / B16.47 ASME Class 150 (PS max=19 bar); ASME Class 300 (PS max=25 bar); AS/NZS 4087 PN 16 / PN21 / PN35; AS 2129 Tab.E / Tab.F; JIS B 2220 10K; connection flanges are not available for all sizes; other flanges on request
Flange Sealing Face
EN 1092 Form A / B; ASME RF, FF
Top Flange
EN ISO 5211
Face-to-Face Standard
EN 558 Series 13; ISO 5752 Series 13
Operating Standard
EN 593
Sealing Class
EN 12266 Leakage rate A; ISO 5208 Category 3
Operating Temperature Range
-40 °C to +200°C (depending on pressure, media, and materials)
Maximum Working Pressure
Max. 25 bar
Maximum Differential Pressure
Max. Δp 25 bar
Vacuum Application
Up to 1 mbar absolute pressure

Application scenarios

  1. Wastewater Treatment Plant Process Pipelines

    Used for media isolation in influent and effluent lines and in-plant process pipelines of wastewater treatment plants. The F012-A is a double flanged butterfly valve with nominal sizes DN 50 to DN 1400 and a maximum working pressure of 25 bar, meeting the installation and isolation requirements of pipelines at different scales.

  2. Water Supply and Drainage Pumping Stations and Transmission Mains

    Used for sectional shutoff and equipment isolation in water supply and drainage pumping stations, transmission mains, and long-distance pipelines. The F012-A supports DN 50 to DN 1400 sizes, can be installed in any orientation, and supports single flange installation.

  3. Desalination System Pipelines

    Used for media isolation in water transmission mains, treatment unit connecting lines, and pumping pipelines in desalination plants. The F012-A features a double flanged construction, supports multiple flange standards, and can be installed in any orientation.

  4. Offshore Facilities and Ship Pipelines

    Used for media shutoff in offshore facility and ship pipelines. The F012-A features a double flanged butterfly valve construction, supports installation in any orientation, and has a vulcanized seat and single-stem design, making it suitable for high-pressure pipeline applications.

  5. Power Plant Water Systems

    Used for on/off isolation in cooling water, makeup water, and related process water pipelines within power plants. The F012-A offers a maximum working pressure of 25 bar and an operating temperature range of -40°C to +200°C, depending on pressure, media, and materials, with sealing to EN 12266 Leakage rate A and ISO 5208 Category 3.

Selection points

  1. Double Flanged Construction with Single Flange and Any-Orientation Installation

    The F012-A features a double flanged design, supports single flange installation, and can be installed in any orientation, making it suitable for applications requiring flexible pipeline layouts or single flange connections.

  2. Vulcanized Seat and Single-Stem High-Pressure Construction

    With a vulcanized seat and single-stem construction, the valve delivers a maximum working pressure of 25 bar and a maximum differential pressure of 25 bar, suitable for fluid pipelines under the corresponding pressure and differential pressure conditions.

  3. Triple Bushings and Adjustable Bushings under Specific Conditions

    The product is equipped with triple bushings; for sizes DN600 and below with a working pressure of 16 bar or higher, adjustable bushings are supported and should be confirmed according to the specific size and pressure conditions during selection.

  4. Vacuum Capability Down to Low Absolute Pressure

    The product supports vacuum applications down to 1 mbar absolute pressure; suitability should be confirmed in combination with pressure, media, and material conditions.

  5. EN ISO 5211 Standard Top Flange

    The top flange complies with EN ISO 5211, allowing easy pairing with actuators that feature the corresponding standard interface.

FAQ

What nominal sizes and pressure ranges does the F012-A double flanged butterfly valve cover?

The F012-A covers nominal sizes DN 50 to DN 1400, with a maximum working pressure of 25 bar and a maximum allowable differential pressure of Δp 25 bar. The actually usable pressure range should also be matched to the selected size, connection flange, media, and valve material conditions.

Which flange standards can the F012-A be connected to?

The valve matches flange standards including EN 1092 PN 6/10/16/25, ASME B16.5/B16.47 Class 150 and Class 300, AS/NZS 4087 PN 16/PN21/PN35, AS 2129 Tab.E/Tab.F, and JIS B 2220 10K. ASME Class 150 has a maximum working pressure of 19 bar, and Class 300 has a maximum working pressure of 25 bar; not all flange connections are available for all sizes.

Can the F012-A double flanged butterfly valve be used for single flange installation and different mounting orientations?

Yes. The F012-A features a double flanged design, supports single flange installation, and can be installed in any orientation. Installation should still be confirmed in consideration of the pipeline layout, actuator space, flow direction, and on-site support conditions.

Which sealing standards does the F012-A comply with?

The F012-A meets the EN 12266 Leakage rate A and ISO 5208 Category 3 sealing class requirements, with EN 593 as the operating standard. The valve features a vulcanized seat and single-stem construction with a triple bushing design, making it suitable for high-pressure service.

Can the F012-A be used for vacuum and high- or low-temperature media?

The valve can be used in vacuum service down to 1 mbar absolute pressure, with an operating temperature range of -40°C to +200°C. Temperature suitability is affected by the combination of pressure, media, and materials, and should be confirmed according to the actual model and application conditions.

Contact Us

Send model, duty, or sourcing request. We will respond with next step.

Or call / email us directly